Blog
A package-level checklist for topside cooling design

1. Identify the exact package and its cooling surface
Start this topside cooling design checklist for power semiconductor packages by confirming the full device part number, package designation, pinout, and revision. Then identify which package face is intended to contact the cooler. Similar-looking packages may have different constructions or cooling instructions, so do not assume that any broad, flat surface is a thermal contact.
Check the package drawing and device documentation before selecting a heatsink or cold plate. Record the contact footprint and any keep-out areas; the wrong face or an oversized contact can create mechanical or electrical problems.

2. Check the package-specific thermal and mounting guidance
Use the datasheet and any package assembly guide for the exact device. Confirm the thermal limits, the specified measurement point, contact-area requirements, and mounting instructions. In a topside cooling design, values and conditions must match the intended heat-flow path; a thermal resistance measured for a different package interface may not represent your assembly.
Keep the document revision with your design records. If the component is a SiC MOSFET, start with its package and thermal information rather than assuming guidance applies across the SiC MOSFET range.

3. Choose a thermal interface that suits the package
Select an interface material (TIM) that fits the package surface, contact pressure, operating temperature, and electrical-isolation needs. The purpose is to fill small surface irregularities, not to create a thick layer. Check the material’s specified thickness range and application method, then follow those instructions consistently.
Too little material can leave gaps; too much can increase the thermal path or spread beyond the intended area. For high-voltage designs, also confirm whether the TIM is electrically insulating or conductive before it enters the assembly.

4. Match the heatsink face to the device contact area
Compare the cooler’s contact footprint with the package’s designated cooling surface. Check alignment, flatness, and surface finish against the package and interface-material guidance. A cooler that is too small may not cover the intended area; a misaligned or uneven face can produce inconsistent contact.
Inspect the complete contact area for burrs, debris, or damage before assembly. If the design uses a cold plate, check that its mounting features do not obstruct the device’s specified thermal contact.

5. Preserve electrical isolation across the thermal stack
Determine whether the cooling surface is electrically connected to a device terminal or another part of the circuit. If isolation is required, include an insulating layer only when the device and system requirements allow it, and account for its thermal effect as part of the stack.
Check the isolation rating and installation requirements of each layer, then assess the assembled configuration—not just the material in isolation. Keep clearances and creepage paths consistent with the system’s voltage and applicable design requirements. For diode-based designs, review the exact package details for the selected SiC high-voltage diodes.

6. Apply mounting pressure evenly within package limits
Follow the specified fastener sequence and torque or pressure limits for the package. Use the recommended hardware and tighten progressively if the assembly instructions call for it. Uneven loading can tilt the device, distort the interface layer, or stress the package.
Do not substitute a guessed torque for a package-specific value. If multiple devices share a cooler, check how the mounting arrangement distributes force across each contact area and whether tightening one device shifts another.

7. Validate the assembled stack under operating conditions
Test the complete assembly in representative operating conditions, including the expected electrical loading and cooling environment. Measure at documented locations, allow the system to reach a defined thermal condition, and compare readings with device limits and design expectations. Record the ambient or coolant conditions and the measurement method so results can be repeated.
A case or cooler temperature alone does not establish junction temperature. Use the device’s applicable thermal data and account for the heat path between the measurement point and the junction. For power conversion designs, component category matters too: the silicon MOSFET range is a separate option to assess against the application’s electrical and thermal requirements.
Topside Cooling Design FAQs
How do I estimate junction temperature from a measured case temperature?
Estimate junction temperature using the measured case temperature plus dissipated power multiplied by the applicable junction-to-case thermal resistance. Confirm that the resistance and measurement point match the package’s specified heat-flow path.
Which thermal resistance values in a datasheet apply to a topside-cooled package?
Use the thermal resistance values whose endpoints and test conditions match the intended path from junction to the topside contact and cooler. Do not apply a junction-to-board or junction-to-case value to a different interface without checking its definition.
How should I account for thermal interface material aging?
Use the TIM manufacturer’s aging and operating-condition guidance, and validate the assembled stack over the product’s expected temperature and duty conditions. Recheck thermal performance if the interface changes, degrades, or is disturbed during service.
Can a topside-cooled device be used with a liquid-cooled cold plate?
Yes, if the package documentation and system design support the contact and mounting arrangement. Verify interface layers, electrical isolation, pressure limits, and coolant-side operating conditions for the complete assembly.
Does airflow around the package affect topside cooling performance?
Yes. Airflow can affect heat transfer from exposed package and cooler surfaces, so test the assembly with representative enclosure, fan, and nearby-component conditions rather than relying on an isolated bench setup.
How can I tell whether a thermal interface material is electrically conductive?
Check the material’s technical documentation for electrical resistivity, dielectric strength, and any stated conductivity. Do not infer electrical behavior from its appearance or thermal performance.
What temperature sensors are suitable for testing a power semiconductor cooling stack?
Use a calibrated sensor suited to the measurement point, temperature range, and response time, such as a thermocouple or resistance temperature detector. Mount it consistently and avoid letting the sensor itself disrupt the thermal contact.
When should I repeat thermal validation after changing the heatsink or interface material?
Repeat validation whenever a change can alter contact, thermal resistance, electrical isolation, or mounting force. This includes changes to the cooler geometry, TIM type or thickness, insulating layer, fasteners, or assembly process.
Use test results to refine the design
If measurements differ from expectations, inspect the contact pattern, TIM application, mounting alignment, and isolation layers before changing the device. Change one factor at a time where practical, then repeat the test under comparable operating conditions. Keep the final assembly details and results together so the validated configuration can be reproduced.
Review Your Cooling Requirements
Compare the package, voltage, interface, and mounting requirements against relevant device information before finalizing the thermal stack.

Irina Kulkarni writes about power semiconductor technologies and their role in efficient power conversion. She has a background in electrical engineering and experience evaluating silicon carbide devices for high-voltage applications. Her coverage includes SiC diodes, MOSFETs, device selection, and practical design considerations for engineers working on EV, renewable energy, and data centre systems. She aims to make technical guidance precise, useful, and grounded in real design trade-offs.